Your boiler should quietly keep your home warm and comfortable. However, when an error code suddenly appears on your Ariston display, everything comes to a halt. There is no hot water, no heating, just confusion and cold. If you've found yourself staring at codes like 501, 607, or 304, you're probably wondering what they mean and what to do next.
You're not alone—and you don't have to figure it out on your own.
Ariston boilers are known for efficiency, but like any appliance, they can develop faults. The good news? These error codes are your boiler's way of telling you exactly what's wrong. With the proper support, most issues can be resolved quickly, sometimes with a simple reset, other times with a qualified repair.
Whether you own an Ariston E Combi Evo, another Ariston combination boiler, or you're researching issues before a combi boiler installation, this blog has you covered with clear answers, quick solutions, and expert insights.
Need urgent help with your Ariston boiler in London? Contact Maintracts Services for fast, expert support. We've been solving heating problems since 1974 and offer same-day repairs and servicing from Gas Safe registered engineers. Contact us on 020 8682 2244 or email info@maintracts.co.uk for expert advice and assistance.
Our team of expert heating engineers boasts extensive experience in dealing with Ariston boilers, offering a wide range of services including installation, servicing, and repair. As London boiler installers, we are dedicated to ensuring your heating system runs smoothly—no matter the issue.
What Are Ariston Boiler Fault Codes?
Ariston boiler fault codes are alphanumeric codes displayed on the boiler's digital screen when something disrupts its regular operation. These codes are designed to help boiler engineers diagnose problems efficiently, whether they are related to gas supply, ignition issues, low pressure, or blocked components.
Each fault code points to a specific issue. For example:
Error Code | Meaning | Likely Cause | Suggested Action |
501 | Ignition failure | No gas supply, faulty ignition electrode, or burner issue | Check gas supply, reset boiler, call engineer |
607 | Gas valve or air pressure switch fault | Malfunctioning valve or sensor issue | Requires professional diagnosis and repair |
304 | Water circulation error | Pump failure or airlock in the system | Bleed radiators, check pump, call service |
103 | Low system pressure | Leak or insufficient pressure | Top up boiler pressure using a filling loop |
108 | Pressure too low | Leak, faulty pressure gauge | Repressurise the system, check for leaks |
109 | Pressure too high | Overfilled system or expansion vessel issue | Bleed radiators, call a technician if persists |
305 | Flow temperature sensor error | Faulty temperature sensor or wiring issue | Needs sensor inspection or replacement |
306 | Return temperature sensor fault | Wiring fault or damaged sensor | Contact a Gas-safe engineer |
507 | Flame detected when the boiler is off | Faulty PCB or sensor | Call the boiler engineer immediately |
501P | Repeated ignition failure | Severe ignition issue or blocked flue | Call boiler engineer |
302 | No system flow | Closed valve, airlock, or pump problem | Check valves and pump |
601 | The flue gas thermostat triggered | Overheating, blocked flue | Turn off the boiler and seek professional help |
610 | Fan malfunction | Fan failure or wiring problem | Engineer required |
611 | Faulty air pressure switch | Pressure switch or tube fault | Check the flue and air intake system |
103P | Persistent low-pressure fault | Ongoing leak or pressure loss | Leak detection and professional repair |
5P1 | Short circuit on flame detection electrode | Electrical issue or faulty component | Call engineer for electrical diagnostics |
How To Reset Your Ariston Boiler After A Fault Code
Resetting your Ariston boiler is a simple way to clear minor glitches or temporary faults. If your boiler is showing an error code, here's how to safely attempt a reset:
Step-By-Step: Using The Ariston Boiler Reset Button
- Locate the reset button – On most models, including the Ariston E Combi Evo, the reset button is either on the control panel or behind a flap.
- Press and hold – Press and hold the reset button for around 5–10 seconds.
- Wait and observe – The boiler should reboot and attempt to operate normally. Watch for the reappearance of any fault codes.
If the fault code persists after a reset or the boiler continues to turn off, it may indicate a more serious issue that requires professional assistance. Don't repeatedly reset the boiler, as it can mask a serious problem or cause further damage.
Read more about glow-worm boiler error codes and Baxi boiler error codes.
Get 100% Transparency And Best Results With Maintracts Services
At Maintracts, we take pride in delivering professional, efficient, and reliable boiler services. With decades of hands-on experience and a reputation built since 1974, we ensure every job, whether it's a minor fault or a complete Ariston boiler installation, is handled with expertise, transparency, and care.
- We get the urgency: Boiler faults can't wait—especially in winter.
- Expert engineers: Gas Safe registered, with experience in all Ariston models.
- Precise diagnosis: No jargon, no guesswork—just honest advice.
- End-to-end support: From quick resets to complete installations.
- Protect your home: Prevent long-term damage and restore comfort fast.
Contact us on 02086822244 or email info@maintracts.co.uk for reliable and professional services.
FAQs
What does error code 501 mean on an Ariston boiler?
Error code 501 typically means your boiler has failed to ignite. This can be due to gas supply interruptions, blocked burner jets, or faulty ignition components. Check your gas supply and contact a boiler engineer if the issue persists.
Why is my Ariston boiler showing an ignition fault?
Ignition faults often stem from a lack of gas, a faulty ignition electrode, or a blocked flue system. If your Ariston gas boiler repeatedly fails to ignite, it's best to call a certified gas boiler servicing technician.
How do I fix low pressure on an Ariston boiler?
If your boiler shows a low-pressure fault (often below 1 bar), you can top it up using the external filling loop. Carefully open the valves and observe the pressure gauge as it rises to between 1.0 and 1.5 bar. If pressure continues to drop, there may be a leak, and you'll need a central heating service check.
Is it safe to use my Ariston boiler when a fault code is displayed?
No, using a boiler with a fault code can be dangerous, especially if it's a gas or ignition-related issue. Always follow safety guidelines and consult qualified boiler engineers before continuing use.
How often should I service my Ariston boiler to prevent errors?
Annual gas boiler servicing is recommended to keep your Ariston boiler running efficiently and catch minor problems before they turn into major faults. Regular servicing extends the lifespan of your boiler and maintains its warranty.
Who can I contact for Ariston boiler repairs in London?
You should always contact Gas Safe registered boiler engineers for Ariston boiler repairs. Many professional companies in London offer combi boiler installation, servicing, and repairs. Look for local specialists with experience in Ariston combination boiler systems.
What does error code 607 mean on an Ariston boiler?
Error code 607 generally indicates a malfunction in the gas valve or issues with the air pressure switch. It often requires a specialist diagnosis, as both components are critical to safe operation.
Why does my Ariston boiler keep turning off with a fault code?
If your boiler keeps switching off and displaying a fault, it could be due to overheating, low pressure, or a blocked heat exchanger. This is common in older systems or those that haven't had regular servicing.
Are Ariston boiler error codes related to issues with the gas supply?
Yes, several error codes can point to gas supply problems—especially ignition and burner faults. If you suspect a supply issue, check other gas appliances and call our gas provider or a qualified engineer. Contact us to receive a quick quote.
What does a flashing red light on my Ariston boiler mean?
A flashing red light usually indicates a serious fault, often related to ignition or overheating. Do not ignore it. Switch off the boiler and consult a technician.
Should I switch off my Ariston boiler when a fault code appears?
Yes. Turning off the boiler is a safe first step when a fault code appears—especially if it's gas-related. After switching it off, try a reset. If the issue persists, consider seeking professional help.
Where can I find reliable Ariston boiler engineers in my area?
Start by checking local listings, trade review platforms, or asking neighbours. Look for Gas Safe registered technicians who specialise in Ariston boiler servicing, repairs, and new boiler installations.
Call 020 868 22244
to speak directly to an
experienced professional.
Delivering customer
excellence since 1974.